For a replacement, compare the terminal arrangement and mounting positions with the original unit. The electrical table gives the input and output ratings separately from the insulation test voltages.
Product specifications
| Parameter | Specification |
|---|---|
| Model | CZCL A-200AF-5 |
| Rated output | 5 V DC, 40 A |
| Output power | 200 W maximum |
| Mains input | 200–240 V AC, 47–63 Hz |
| Input-to-output insulation | 3.0 kV AC |
| Input-to-FG / output-to-FG insulation | 1.5 kV AC / 0.5 kV AC |
| Power factor at 230 V AC | 0.50 |
| Leakage current at 230 V AC | 0.30 mA |
| Working temperature | −30 to +60 °C |
| Storage temperature and humidity | −40 to +100 °C, 20–95% RH |
| Protection | Undervoltage, overload and short circuit |


Download CZCL A-200AF-5 specification (PDF)
Frequently asked questions
Where can I find the A-200AF-5 specification?
Use the PDF below the product photos. Check the model and terminal layout against the supply in your cabinet.
What does the 3.0 kV AC figure refer to?
It is the listed input-to-output insulation test voltage. The operating mains input is 200–240 V AC.
What DC load is the A-200AF-5 rated for?
This model is listed for a 5 V DC load of up to 40 A, with a maximum output of 200 W.







Reviews