CON5/6 is identified as the +3.8 V connection and CON2 as +2.8 V. The table gives ±5% for each rail. The PCB has a conformal coating and the protection list includes short circuit, overcurrent and overtemperature.
Product details
| INPUT | |
| Input Voltage Range | 90Vac to 264Vac |
| Rated Input Voltage | 100Vac to 240Vac |
| Input Frequency Range | 47Hz to 63Hz |
| Rated Input Frequency | 50Hz to 60Hz |
| Input Current | Max. 3.5A at 90Vac input at Full Load |
| Inrush Current | 60A (TYP. peak) at 240Vac |
| Power Factor | ≧0.99at 100Vac, ≧0.96 at 230Vac |
| Efficiency | 83% min@220Vac ,Full Load |
| OUTPUT | |||
| Output Power | 200W | ||
| Output Channel | Rated Output Voltage | Voltage | Rated Current |
| CON5/6(+)(-) | +3.8Vdc | ±5% | 100Vac to 240Vac; 0A-30A |
| CON2(+)(-) | +2.8Vdc | ±5% | 100Vac to 240Vac; 0A-30A |
| Dimensions | 210.0mm x 58.0mm x 26.0mm±0.5mm |
Download the module specification (PDF)
Frequently asked questions
Can the two 30 A figures be added as one output rating?
The table lists 0–30 A for each rail at 100–240 V AC and a 200 W total output rating. Check each rail and the combined power requirement.
What are the enclosure dimensions?
The listed dimensions are 210.0 × 58.0 × 26.0 mm, with ±0.5 mm printed in the dimension entry.
Is −40 °C the continuous operating minimum?
The feature summary identifies −40 °C as the start-up condition and −30 to 70 °C as the operating range.




Reviews
There are no reviews yet.