One option is labeled 200–240 V input. The other lists 100–120 V and 200–240 V input bands. Both are offered under A-200W-5, so the model name alone does not identify the input configuration.
Product specifications
| Parameter | Specification |
|---|---|
| Model | CZCL A-200W-5 |
| Output | 5 V DC, 40 A |
| AC input options | 200–240 V only, or 100–120 / 200–240 V |
| Frequency | 47–63 Hz |
| Case / dimensions | 812 / 222 × 115 × 50 mm |
| Cooling | Forced air, built-in DC fan |
| DC adjustment | ±10% of rated output voltage |
| Line regulation | ≤0.5% at full load |
| Cold-start inrush | 40 A at 230 V AC |
| Overload protection | 110–150%, shutdown with AC power cycle to restart |
| Load at +60 °C | 60% |
| Typical rise / hold-up time | 50 ms / 20 ms at full load |


Download CZCL A-200W-5 specification (PDF)
Frequently asked questions
Which A-200W-5 option should I choose for 110 V AC?
Select the option that explicitly lists 100–120 V and 200–240 V. The option marked only 200–240 V is for the higher input band.
Where can I see the price for my input version?
Choose the required AC input option in the model-number menu. Check that selection before adding the supply to your cart.
How does the A-200W-5 restart after an overload shutdown?
The specification calls for cycling the AC supply after the cause of the overload has been corrected.