STH100 environmental sensor for the M-MFN02
The Mooncell STH100 is a temperature and humidity probe designed to work with the M-MFN02 multifunction card. It monitors the surrounding environment and is supplied with a 1.5 m cable for the documented card connection.
Use the measurement ranges when assessing the readings required by an installation. The operating-temperature range describes the environment in which the sensor works and is wider than its temperature measurement range. The PDF does not provide accuracy, cable-extension limits or an IP rating, so those values have not been added.
Technical specifications
| Parameter | Specification |
|---|---|
| Model | Mooncell STH100 |
| Function | Ambient temperature and humidity monitoring |
| Compatible card named in PDF | Mooncell M-MFN02 multifunction card; feature list also abbreviates it as MFN02 |
| Rated voltage | 5.0 V |
| Separate external power supply | Not required according to the specification |
| Temperature measurement range | −20°C to +75°C |
| Humidity measurement range | 0–99% RH |
| Operating ambient temperature | −25°C to +80°C |
| Operating ambient humidity | 0–99% RH |
| Standard cable length | 1.5 m |
| Net weight | 92 g |
| Package quantity in PDF | 1 STH100 temperature/humidity sensor |
Product images and specification download
Frequently asked questions
Which Mooncell card does the STH100 connect to?
The specification identifies the M-MFN02 multifunction card, also abbreviated as MFN02 in its feature list. It does not establish compatibility with every controller or receiving-card sensor port.
Does STH100 need a separate power adapter?
No separate external power supply is required according to the PDF. The sensor has a 5.0 V rated voltage and is intended for the specified multifunction-card connection.
What is the temperature measurement range?
The measurement range is −20°C to +75°C. The wider −25°C to +80°C figure is the operating-environment range, not an extension of the specified measurement range.
How long is the supplied cable, and can it be extended?
The standard cable length is 1.5 m. The supplied document does not state an allowable extension length or measurement accuracy after extension; confirm the permitted wiring before adding cable.
Is STH100 waterproof or suitable for direct rain exposure?
The specification gives humidity ranges but no IP or waterproofing rating. Do not interpret the 0–99% RH measurement range as approval for direct water exposure; choose the installation location and protection accordingly.





Reviews