For cabinet sizing, use the rated AC input range and the input-voltage versus load curve in the specification. The unit uses natural cooling and mounts on a metal plate to dissipate heat.
Product specifications
| Parameter | Specification |
|---|---|
| Model | JPS200PV5.0A33 |
| Output | 5.0 V DC, 0–40 A |
| Output power | 200 W |
| Rated AC input | 100–240 V, 50–60 Hz |
| Input range in main specification | 60–264 V AC, subject to the input/load curve |
| Voltage accuracy | ±2% |
| Ripple and noise | ≤250 mV peak-to-peak |
| Working temperature | −30 to +60 °C |
| Cooling | Natural cooling on a metal mounting plate |


Download G-Energy JPS200PV5.0A33 specification (PDF)
Frequently asked questions
Can I use the full 200 W across the entire 60–264 V range?
Check the input/load curve for the planned mains voltage. The main specification lists 60–264 V AC, while the electrical table gives a rated range of 100–240 V AC.
How should the supply be mounted for cooling?
Mount it on a metal plate. If the housing exceeds 80 °C, the manufacturer calls for a larger heat-dissipation area or a reduction in load.
Which output ripple limit applies to this model?
G-Energy specifies up to 250 mV peak-to-peak for the JPS200PV5.0A33.









Reviews
There are no reviews yet.