When planning a replacement, check the cabinet’s AC feed and the ambient temperature at the supply. The downloadable specification includes separate input-voltage and temperature load curves.
Product specifications
| Parameter | Specification |
|---|---|
| Model | J300V5.0A4 |
| Rated DC output | 5.0 V, 0–60 A |
| Output power | 300 W |
| Nominal AC input | 200–240 V, 50–60 Hz |
| Input range in main specification | 180–264 V AC |
| Output accuracy | ±5% |
| Ripple and noise at 25 °C | ≤200 mV peak-to-peak |
| Efficiency | ≥86% at 220 V AC, 25 °C and full load |
| Working temperature | −30 to +50 °C, subject to the load curve |
| Cooling | Natural cooling |





Download G-ENERGY J300V5.0A4 specification (PDF)
Frequently asked questions
Will the J300V5.0A4 work on a 120 V feed?
120 V falls below the 180 V lower input limit. The nominal supply is 200–240 V AC.
What load was used for the published efficiency figure?
G-Energy specifies at least 86% efficiency with a 220 V AC input at 25 °C and full output load.
Where can I check cabinet mounting dimensions?
The mechanical section of the downloadable J300V5.0A4 specification shows the enclosure dimensions and mounting-hole positions in millimetres.









Reviews