For a front-service job, first confirm that the module can be removed by suction. The X-01 has a backpack-style carrying arrangement. The demonstration shows how the tool is handled at the display face.
Product specifications
| Parameter | Specification |
|---|---|
| Model | EagerLED X-01 |
| Service method | Vacuum, from the front |
| Charger input | 100–240 V |
| Charger output | 25.2 V |
| Maximum continuous charging current | 1 A at 25.2 V |
| Battery energy | 43.2 Wh |
| Continuous discharge | 12 minutes in laboratory testing |
| Working environment | −20 to +45 °C, 15–85% RH |





Frequently asked questions
How long does the X-01 run continuously?
The laboratory continuous-discharge result is 12 minutes. Runtime varies with operating conditions.
What charger ratings should I check?
The listed charger accepts 100–240 V and delivers 25.2 V. Maximum continuous charging current is 1 A.
How does the switch guard help during module removal?
The guard helps prevent accidental activation when carrying or positioning the tool. Consult the module instructions before applying suction.










Reviews