Use the full model suffix when checking a replacement. Compare the current and efficiency at the line voltage used in the cabinet. The circuit board has a conformal coating.
Product details
| Parameter | Specification |
|---|---|
| Input Voltage Range | 200 V AC to 264 V AC |
| Rated Input Voltage | 200 V AC to 240 V AC |
| Input Frequency Range | 47 Hz to 63 Hz |
| Rated Input Frequency | 50 Hz to 60 Hz |
| Input Current | Max3.5 A at AC230V input and full load |
| Inrush Current | ≤80 A (TYP. peak) at 230 V AC |
| Power Factor | ≥0.5 at 230 V AC |
| Efficiency | >86.0% at 230 V AC |
| PCB treatment | Conformal coating |
| Operating temperature | -25 to +70 °C |

Download the module specification (PDF)
Frequently asked questions
What is the rated AC input for L300V4.6A2?
The rated input is 200 V AC to 240 V AC. The wider input range in the same table is 200 V AC to 264 V AC.
How does input current change with supply voltage?
The manufacturer’s listed conditions are Max3.5 A at AC230V input and full load. Keep the input voltage and load condition with each current figure.
Under what conditions is the efficiency specified?
At the input voltages and load conditions in the table, the specified figures are >86.0% at 230 V AC.




Reviews
There are no reviews yet.