MQ200PC5A supply: specification comparison and installation
The Rong-Electric MQ200PC5A is an LED display power supply with a nominal 5 V DC output, natural cooling and a required auxiliary heat-dissipation plate. The original overview identifies undervoltage, current-limit and short-circuit protection.
Rating discrepancy: the original page table and model-matched PDF disagree on output power/current, input range and ripple limit. The table below keeps those sources separate. Additional technical entries come from the PDF; confirm the actual unit label and revision before using either set of conflicting ratings.
Technical specifications
| Parameter | Specification |
|---|---|
| Model | Rong-Electric MQ200PC5A |
| Nominal output voltage | 5.0 V DC |
| Power / current — source difference | Model-matched PDF: 200 W, 0–40 A; original page table: 300 W, 0–60 A |
| AC input — source difference | PDF: 200–240 V AC rated, 176–264 V AC operating range; original page: 160–264 with a Vdc heading |
| Input-graph note | The PDF graph starts at 170 V AC, below its 176 V table limit; confirm the actual unit before using a lower input |
| Input frequency | 47–63 Hz |
| Output-voltage range | 4.9–5.1 V DC |
| Ripple/noise — source difference | PDF: ≤150 mVp-p; original table: ≤200 mVp-p |
| Ripple test conditions in PDF | Full load; 20 MHz bandwidth; 0.10 µF ceramic plus 10 µF electrolytic capacitor at output |
| Overall regulation | ±2% |
| Voltage / load regulation in PDF | ±1% / ±1% |
| Efficiency | ≥85.5% at 220 V AC and full load, room temperature |
| Power factor | ≥0.95 at full load |
| Maximum input / inrush current | ≤3.0 A / ≤60 A |
| Turn-on delay / rise time | ≤2,500 ms / ≤250 ms |
| Hold-up time | ≥10 ms at 220 V AC |
| Protection | Input undervoltage; current-limit threshold 48–76 A; short-circuit protection with hiccup/automatic recovery |
| Working temperature | −30°C to +70°C; temperature curve reduces load above 50°C, reaching 75% at 70°C |
| Auxiliary heat dissipation | 200 × 200 × 3 mm plate beneath the power supply |
| Cooling / working humidity | Natural cooling / 10–90%, non-condensing |
| Altitude | 0–3,000 m |
| Dimensions / unit weight | 190 × 82 × 30 mm, ±1.0 mm / 420 g |
| Input / output terminal order | Input: N, N, L, L, earth. Output: GND, GND, GND, +5 V, +5 V, +5 V; facing each connector left to right |
| Source | MQ200PC5A approval specification V1.0 and original page; conflicting values are labeled separately |
Product images and specification download

Rong-Electric MQ200PC5A Display ultra-thin power supply Specification
Frequently asked questions
Is MQ200PC5A a 200 W or 300 W supply?
The linked MQ200PC5A PDF explicitly specifies 200 W and 0–40 A at 5 V. The original page table instead listed 300 W and 0–60 A. These values conflict; verify the unit label and hardware revision before selecting a replacement or applying the higher load.
What input voltage should be checked?
The model-specific PDF input table states 176–264 V AC, with 200–240 V AC rated input. The original page gave 160–264 under a Vdc heading, and the PDF graph starts at 170 V AC. Do not combine these into an expanded operating range.
Does the MQ200PC5A need a heat-dissipation plate?
Yes. Both the original environmental table and PDF specify a 200 × 200 × 3 mm auxiliary plate under the supply. The installation must also account for the cabinet temperature.
Can it run at full load at 70°C?
No. The temperature curve reduces load above 50°C and reaches 75% at 70°C. Use that curve with the confirmed unit rating and the required heat-dissipation plate.
Where can I find the original specification and terminal layout?
The original specification link remains below the product image. The PDF includes the input/output connector definitions and mounting drawing; its identified rating differences are documented on this page for checking against the actual unit.