Σύντομη απάντηση: The Mean Well LRS-350-24 delivers 24 V at 14.6 A (350.4 W). The LRS-350-5 delivers 5 V at 60 A (300 W), and the LRS-350-12 delivers 12 V at 29 A (348 W). Every LRS-350 model has the same 215 × 115 × 30 mm case, a built-in fan and a 115/230 VAC input selector switch. The LRS-200 uses the same footprint and cools by free air convection, with no fan. For LED display modules you need the 5 V (or 4.2/4.5 V) versions. The 12, 24 and 48 V models are for LED strips, drivers, automation and other 12-48 V loads.
This page collects the LRS figures buyers ask about most: output current per voltage, wattage, case size, cooling and input type. It then shows how to size 5 V supplies for an LED screen. Ratings come from Mean Well’s LRS-350 and LRS-200 datasheets and the LRS series catalog. Last checked: November 2026.
Mean Well LRS-350 specifications by output voltage
The LRS-350 is a 350 W-class, single-output, enclosed switching power supply in a 30 mm low-profile (1U) case. The voltage is the number after the last dash, so LRS-350-24 = 24 V. The low-voltage models are current-limited at 60 A, which is why the 3.3, 4.2 and 5 V versions are rated below 350 W.
| Μοντέλο | τάση εξόδου | Ονομαστικό ρεύμα | Ονομαστική ισχύς | Τυπική χρήση |
|---|---|---|---|---|
| LRS-350-3.3 | 3.3 V | Η 60 | 198 W | Low-voltage logic, special LED modules |
| LRS-350-4.2 | 4.2 V | Η 60 | 252 W | Indoor LED modules specified for 4.2 V |
| LRS-350-5 | 5 V | Η 60 | 300 W | LED display modules, receiving cards |
| LRS-350-12 | 12 V | Η 29 | 348 W | 12 V LED strips, CCTV, 12 V equipment |
| LRS-350-15 | 15 V | Η 23.2 | 348 W | 15 V industrial loads |
| LRS-350-24 | 24 V | Η 14.6 | 350.4 W | 24 V LED strips, PLCs, motors, signage lighting |
| LRS-350-36 | 36 V | Η 9.7 | 349.2 W | 36 V systems |
| LRS-350-48 | 48 V | Η 7.3 | 350.4 W | 48 V telecom, PoE, motor drives |
Shared LRS-350 ratings: 90-132 VAC or 180-264 VAC input, selected by switch (240-370 VDC with the switch on 230 V). The case is 215 × 115 × 30 mm and the cooling fan is built in. The operating range is -25 °C to +70 °C, with output derating at high temperature. Protection covers short circuit, overload (110-140% of rated power), over-voltage and over-temperature, and the warranty is 3 years. Output voltage is adjustable with the V.ADJ potentiometer; for the 24 V model the range is 21.6-28.8 V.

LRS-50, LRS-75, LRS-100, LRS-150, LRS-200 and LRS-350 compared
Smaller LRS models use smaller cases and have no fan. The table lists the 24 V version of each size, plus the 5 V version where it is relevant for LED screens.
| Σειρές | Μοντέλο 24 V | Μοντέλο 5 V | Case (L × W × H) | Ψύξη |
|---|---|---|---|---|
| LRS-50 | LRS-50-24: 2.2 A, 52.8 W | LRS-50-5: 10 A | 99 82 × × 30 mm | Δωρεάν μεταφορά αέρα |
| LRS-75 | LRS-75-24: 3.2 A, 76.8 W | LRS-75-5: 14 A | 99 97 × × 30 mm | Δωρεάν μεταφορά αέρα |
| LRS-100 | LRS-100-24: 4.5 A, 108 W | LRS-100-5: 18 A | 129 97 × × 30 mm | Δωρεάν μεταφορά αέρα |
| LRS-150 | LRS-150-24: 6.5 A, 156 W | LRS-150-5: 22 A | 159 97 × × 30 mm | Δωρεάν μεταφορά αέρα |
| LRS-200 | LRS-200-24: 8.8 A, 211.2 W | LRS-200-5: 40 A, 200 W | 215 115 × × 30 mm | Free air convection (fanless) |
| LRS-350 | LRS-350-24: 14.6 A, 350.4 W | LRS-350-5: 60 A, 300 W | 215 115 × × 30 mm | Ενσωματωμένος ανεμιστήρας |
Input type matters when you replace a unit. LRS-50, LRS-75 and LRS-100 accept universal 85-264 VAC input. The larger models have a 115/230 VAC selector switch on the side. Set it to your mains voltage before switching on: a unit left on 115 V and connected to 230 V mains will be damaged.
LRS-200 or LRS-350? Both share the same mounting footprint. Choose the fanless LRS-200 (40 A at 5 V) for dusty or quiet locations and for sealed cabinets where a fan would only recirculate hot air. Choose the LRS-350 (60 A at 5 V) when you need the extra current and the cabinet has ventilation.
Which Mean Well LRS model does an LED screen need?
LED display modules (P2.5, P3, P4, P5, P10 and so on) and most receiving cards run on 5 V DC. Many indoor modules are specified at 4.2-4.6 V to cut heat and power. So the choice for module power is:
- LRS-350-5 (5 V 60 A) or LRS-200-5 (5 V 40 A) for standard 5 V modules.
- LRS-350-4.2 where the module maker specifies 4.2 V. Alternatively, fine-tune a 5 V unit with V.ADJ, within the module’s allowed range.
- Δεν the LRS-350-24 or LRS-350-12. Feeding 12 V or 24 V into a 5 V module destroys its driver ICs. The 24 V models are for 24 V LED strips, lightbox lighting, controllers with 24 V input, and automation.
Always follow the voltage printed on the module’s back or datasheet. Measure the voltage at the module power connector, not only at the power supply terminals, because long or thin cables drop voltage at 40-60 A.
How many LED modules can one 5 V power supply drive?
- Take the module’s ανώτατο όριο power from its datasheet (full white, maximum brightness), not the average.
- Module current = maximum power ÷ 5 V.
- Usable supply current = rated current × 0.8. Running at about 80% leaves headroom for heat, ageing and inrush.
- Modules per supply = usable current ÷ module current, rounded down.
| Example module max power | Ρεύμα στα 5 V | LRS-200-5 (32 A usable) | LRS-350-5 (48 A usable) |
|---|---|---|---|
| 20 W | Η 4.0 | ενότητες 8 | ενότητες 12 |
| 25 W | Η 5.0 | ενότητες 6 | ενότητες 9 |
| 30 W | Η 6.0 | ενότητες 5 | ενότητες 8 |
| 40 W | Η 8.0 | ενότητες 4 | ενότητες 6 |
The wattages above are examples only; outdoor high-brightness modules usually draw more than indoor ones. Work it out with your own module figure. Count the receiving card on the same rail if it takes power from the supply.
LRS vs PFC supplies and LED-display-specific power supplies
The LRS series is a low-cost general-purpose supply without active PFC. Mean Well notes that the LRS-350 does not meet the EN61000-3-2 harmonic-current limits on its own. That is fine for a few units, but large screens with dozens of supplies, or projects that must pass EU harmonic limits, are better served by PFC models:
- Mean Well PFC and slim options: UHP-200-5 (5 V 40 A), UHP-350-5 (5 V 60 A), RSP-320 5- (5 V 60 A) and NEL-400-5 (5 V 80 A).
- LED-display power supplies designed to mount inside cabinets, for example G-Energy JPS300PV5.0A4, CZCL μονάδες και Megmeet MCP200WS-4.5AB (4.5 V).
When replacing a failed supply in an existing screen, match the original’s output voltage, current and mounting holes first, then choose brand and PFC. See every option in Τροφοδοτικά LED.
Λίστα ελέγχου εγκατάστασης
- Set the 115/230 VAC switch (LRS-150, LRS-200, LRS-350) before applying power.
- Connect the FG (earth) terminal; the metal case must be grounded.
- At 40-60 A, use every output terminal pair and split the load across several short, heavy cables.
- Adjust V.ADJ while measuring at the farthest module, and stay inside the module’s voltage range.
- Leave space for the LRS-350 fan intake and outlet; do not cover the perforated LRS-200 case.
- Do not wire two LRS outputs directly in parallel to get more current. The LRS series has no current-sharing function, so give each supply its own group of modules.
- Check the datasheet derating curve for hot cabinets and high-altitude sites, and reduce the load accordingly.
Need help matching a supply to your modules? Send us the module model, quantity and mains voltage.
Συχνές Ερωτήσεις
What is the output current of the Mean Well LRS-350-24?
14.6 A at 24 V, for 350.4 W. The output can be adjusted from 21.6 to 28.8 V with the V.ADJ potentiometer.
Is the LRS-350-5 300 W or 350 W?
300 W. It is rated 5 V at 60 A; the “350” is the series name. The 12 V and 24 V versions reach about 348-350 W.
Does the Mean Well LRS-350 have a fan?
Yes. The LRS-350 uses a built-in cooling fan. The LRS-200 and smaller LRS models are fanless and cool by free air convection.
Can I use an LRS-350-24 for an LED display?
Not for the LED modules. LED display modules need 5 V (or 4.2-4.6 V); 24 V will damage them. Use the LRS-350-5, LRS-200-5 or LRS-350-4.2 for modules. Keep 24 V models for 24 V devices.
How many P10 or P4 modules can an LRS-350-5 power?
Divide 48 A (80% of 60 A) by the module’s maximum current at 5 V. A module with a 30 W maximum draws 6 A, so one LRS-350-5 powers 8 of them.
Can two LRS power supplies be connected in parallel?
Not directly. The LRS series has no current-sharing function. Split the screen so that each supply feeds its own modules.
Πηγές
- MEAN WELL, LRS-350 series datasheet (rev. 2025-09-12).
- MEAN WELL, LRS-200 series datasheet (rev. 2025-09-12).
- MEAN WELL, LRS series pages in the MEAN WELL product catalog.
- MEAN WELL official website.