Menü - Menu

Colorlight SSR-L16: Az iM9 vagy az RJ11 verzióra van szüksége?

Colorlight SSR-L16 Fényérzékelő érzékelő

Choose the Colorlight SSR-L16 by the host port it will connect to. Colorlight documents an SSR-L16 for an iM9 multifunction-card expansion interface and a separate version with an RJ11 connector for the SENSOR ports of specified A-series players. The two versions can serve a similar light-measurement task, so the host model, port label and cable end are the details to verify before ordering.

This guide is for a service buyer replacing an outdoor display sensor or adding one to an existing Colorlight installation. Use it to build the equipment list and verify that the supplied sensor reports changing ambient light in the intended monitoring software. Have the installer confirm the connection and configuration against the exact hardware revision.

1. Start at the host port on the wall

01. Trace the existing lead to its destination

Identify the board or player that receives the sensor signal. On a replacement job, ask the responsible installer to trace the existing cable and photograph both ends before disconnecting it under the cabinet’s approved service procedure. Record the host model, board revision and the exact label beside the port. A picture of the probe head helps identify the existing sensor family. A picture of the cable end and host interface is more useful for specifying the replacement version.

Az LED-Mall SSR-L16 listing describes the model that connects to an iM9 multifunction card. If your system uses that arrangement, start with the expansion interface documented for your Colorlight iM9. Colorlight also documents an RJ11 SSR-L16 for compatible A-series players. Confirm which version the supplier will ship, especially when a purchase specification just says “SSR-L16 light sensor.”

Colorlight SSR-L16 környezeti fényérzékelő
Identify the connector on the supplied sensor. The probe appearance alone leaves the host version open.

02. Separate the display sender from the sensor endpoint

A site record might name the main LED controller, the player that publishes the content and the board inside the cabinet. The relevant item for this purchase is the hardware with the supported sensor interface. If the player or processor is named on the service ticket but the old sensor cable terminates at an iM9, include both devices in the description. The part number of the display sender alone leaves the cable endpoint unidentified.

If an installation has more than one iM9 or more than one sign, photograph a wider view that shows where the intended host sits. Label the sign or cabinet in the picture and note which host appears in the monitoring software. Two identical boards in the same installation can report different surroundings. The approved configuration should identify the one that will provide the reading for this display.

For a newly specified sign, ask the integrator where the host will be mounted and which sensor devices are expected to share it. Include the chosen player or multifunction card on the bill of materials and identify its intended sensor role. If the configuration is still open, leave the sensor version conditional until the host and its accessible port have been identified. This is easier to resolve on the equipment schedule before the cabinet is assembled.

2. Match the Colorlight SSR-L16 connector version

01. Read the sensor document and the host document together

Colorlight’s standard SSR-L16 V1.2 document describes connection to an iM9 expansion interface. Its separate SSR-L16 RJ11 V1.1 document lists the SENSOR port on A35, A60, A100 and A200 cloud players. The catalog’s Colorlight A200 is one example of the host family named there. Check the exact delivered revision and the label beside its port. The different V numbers identify the two documents and their connection versions. Read the titles and connector sections before choosing.

SSR-L16 iM9 expansion route compared with RJ11 SENSOR route
Illustrative diagram. Match the sensor version to the documented destination on the actual host.
Match the order line to the intended destination
What is at the installation?Documented sensor optionEvidence to put on the order
iM9 with an available supported expansion interfaceStandard SSR-L16 described for iM9 in V1.2.iM9 board revision, occupied and available interfaces, supplier photo of the sensor lead and its mating connection.
Supported A35, A60, A100 or A200 host with its documented SENSOR kikötőRJ11 SSR-L16 described in its V1.1 specification.Exact player model and revision, port label and image of the supplied RJ11 sensor end.
A look-alike modular socket, adapter or unlisted hostEligibility needs manufacturer or supplier confirmation.Both connector photos, full model codes and an approved connection or test record.

02. Use the label and function to identify a modular port

A modular connector can be used for several purposes on an AV device. For example, Colorlight’s A500 V1.4 rear-panel description labels one RJ11 connector as RS232 for a central controller and describes sensor connectivity separately. The A500 player is a reminder to check the label and wiring documentation of any host before drawing a conclusion from socket shape. The RJ11 SSR-L16 document names specific hosts. Use that support list and the matching host specifications.

Ask for written confirmation before using a cable adapter or a different connection arrangement, even if the parts appear to mate. Connector shape, supply and signaling each matter. A retrofit with an unidentified lead should go on the quote as a compatibility check. Provide the photos and labels before ordering it as a replacement accessory.

Some replacements arrive after a player or control cabinet has already changed. If a job was converted from an iM9 installation to a supported A-series player, verify where the technician actually intends to connect the sensor before repeating the previous order. Ask whether the original hardware remains the host and whether the new port will be used. Keep that decision on the revised drawing so the next purchase follows the as-built hardware.

Colorlight iM9 multifunction card product view
The iM9 provides the host interface in the expansion-port installation.

3. Check the cable route when you build the quote

01. Measure the serviceable path

The standard sensor documents describe a 5 m lead, about 16.4 ft. Measure along the route from probe position to the intended host rather than following a straight line between their locations. Include the usable access path, the points where the lead changes direction, and the service allowance specified by the cabinet design. Confirm actual lead length and connector version with the supplier. The available specification for the iM9 variant mentions that its cable can be lengthened. Ask for a supported extension arrangement and limit from the supplier before quoting one.

For example, a route with a 1.8 m rise, 1.25 m sideways run, a 1.1 m drop and 0.55 m service allowance totals 4.70 m, about 15.4 ft. A revised 2.0 m sideways run raises the same planned route to 5.45 m, about 17.9 ft. The first has a small margin against the nominal lead. The second requires a different mounting position or a confirmed extension solution. These are illustrative measurements. Use the actual cabinet and service path to make the decision.

Include the requested probe mount in the quote. The installer needs to know where the probe can sample representative ambient light while staying serviceable. Provide a simple site picture with the sensor position marked, especially if the cabinet has an overhang or is lit by an adjacent fixture. Confirm which parts of the assembly are suitable for the installation conditions and which connections require enclosure protection.

Confirm the planned entry point into the cabinet and how the connector will be routed through or around it. For a retrofit, include a photo of the existing lead’s route around doors or removable panels. A run that clears the frame with the cabinet open can become tight after it closes. If cabinet access is restricted, agree who will service the host and how they will identify the right cable without disturbing other sensors.

Additional view of the Colorlight SSR-L16 light sensor
Record the cable end and lead length from the supplied unit.

02. Give the supplier enough information to identify the supplied part

The quote should identify the sensor version, undisturbed connector end, host model, supporting interface and cable route. If the existing installation uses an iM9, identify which devices already use the expansion interfaces and which one the site can assign to the sensor. If you need the RJ11 variant for a player, confirm it explicitly with the seller. The standard sensor listing describes the iM9 application, so ask for current availability of the specific alternate connector version.

Photos and measurements that resolve the order
Mit kell gyűjteniAmit megoldWhat to ask when missing
Host nameplate and revisionWhich approved host specification applies.Request a clear photo of model and revision marks.
Sensor plug and host port labelWhich connector version and destination have to match.Ask the supplier for a photo of the actual item it plans to ship.
Measured cable path plus service allowanceWhether the standard lead reaches along the approved route.Confirm a compatible route, lead or extension solution before ordering.
Existing device and sensor entry in softwareWhich host and interface the installer should report during testing.Confirm the supported software and the intended controller setup.

4. Verify that the correct sensor produces a changing lux reading

01. Identify the live entry before changing lighting

Use the software appropriate to the supplied host and revision. For supported iM9 installations, Colorlight’s LEDSetting WEB V2.0 manual shows sensor information for the selected multi-function card and identifies readings by expansion interface. A screenshot of an address or an “online” status can help find the host. Ask the commissioning technician to show the sensor type, intended interface and a live reading together. Follow the matching player workflow for the supported RJ11 installation.

Keep other sensors in service and select the intended entry by host and interface name. If the software displays temperature, humidity and light at the same time, show which tile corresponds to the new probe. If a new sensor has moved the approved interface, correct the service record. Do not rely on the order in which several similar sensors appear in a list.

Alternate Colorlight iM9 multifunction card catalog view
Include the board revision and approved expansion interface in the commissioning record.

02. Compare two controlled conditions at the same probe

Ask an installer to verify that the reported lux responds when the probe moves between two safe, repeatable light conditions, such as normal light and temporary shading under the approved site procedure. Record the timestamps and observed readings for each condition, and check the reading after returning to the first condition. Use the same physical sensor and monitored entry throughout. This shows the intended sensor is communicating and responding in the installed configuration. Measurement accuracy and acceptance tolerances require their own agreed reference if the buyer specifies them.

When the reading stays fixed, first check the host identity and the software’s current sensor entry. Compare the connection with the approved port documentation and verify the sensor version on the package. A known working route or properly matched reference sensor can help an installer isolate a fault under the service procedure. Keep the observation separate from any automatic brightness behavior. The scope of this test is the connector choice and the live ambient reading.

What the installer should show before accepting the sensor
Megfigyelt eredményBizonyítékok rögzítésreKövetkező ellenőrzés
Expected host appears and lux changes at the intended interfaceHost label, interface name, light conditions and timestamped readings.Save the evidence with the approved mounting point and lead routing.
Host appears but the intended sensor entry is absentHost revision, actual port, supplied connector and software page.Confirm the specific sensor and host path with the supplier.
A lux value responds on the wrong sign or interfaceHost and sensor entries for each tested sign.Reconcile hardware connections with the site labels and software assignments.
Reading stays fixed through both conditionsObservation interval, displayed value, light conditions and connector photo.Have the installer verify the probe, connection and supported monitoring workflow.

Repeat the two-condition check once the cabinet and the probe are in their normal positions. The service bench may make it easy to shade a sensor while the installed location is affected by an enclosure or other fixture. If the probe cannot be reached safely, have the installation team agree on an appropriate test condition for that location before acceptance. Store photos that show which physical probe was involved.

5. Keep the connector and host details with the spare

01. Make the replacement shelf label unambiguous

Write the full sensor designation, connector version and compatible host on the spare label. Add the physical location or installation group it supports. If a buyer stocks parts for both iM9 and A-series installations, keep separate inventory lines even if the probe housings look similar. Store a copy of the host-side port photo and the successful test result with each configuration, so a later order can reproduce the exact combination.

Have the site team check the identification photos against the delivered part before opening a cabinet. If the supplied lead has a different connector, set it aside and ask the supplier to confirm the order. Handover should give the operator enough detail to request a compatible replacement, including where to find the reported lux value and whom to ask for service access.

02. Keep a short acceptance record for each site

Save the device and interface labels alongside the date, software version and results from the installed test. Include the proposed route and actual route if an installer had to change a mounting point. Agree who maintains the record when a display changes hosts. A service request that includes the prior readings and the exact hardware combination makes a later comparison easier than an order that lists only the sensor family.

For a distributed stock program, have one person confirm which sites use the iM9 route and which have a documented player SENSOR connection. Keep those equipment lists separate. If a new deployment uses a host revision that differs from the validated sample, request compatibility confirmation and a repeat of the live-reading check before stocking additional sensors for it.

Gyakran Ismételt Kérdések

Is the SSR-L16 in the LED-Mall listing the RJ11 version?

The product text describes the iM9 expansion-interface application. If you require the RJ11 version for a supported player, confirm the exact connector and current supply with the seller before ordering.

Does any RJ11 socket on a Colorlight player accept this sensor?

Check the actual port function in the player’s documentation. The RJ11 SSR-L16 document names supported A-series SENSOR ports. Some other modular connectors carry different functions.

Can I order from a photo of the sensor head?

Ask for the cable-end and host-port photos too. A similar probe housing can appear across connector versions, while the host and lead are what the supplier needs to verify.

What if all of my iM9 expansion interfaces are occupied?

List each current interface assignment and the iM9 revision. Ask the supplier for a supported configuration to add the sensor, and test that configuration before ordering a batch.

Does a 5 m lead cover a 5 m straight line?

Measure the actual cable path, including changes of direction and service allowance. A site with a 5 m straight-line distance can require a longer usable lead depending on routing.

Why check the lux reading when the box already recognizes a sensor?

A reading that changes with conditions at the intended probe confirms the actual device and path. Record both the interface entry and the observed response.

Request the exact sensor version

Send LED-Mall your sensor and host photos. Include the controller or player model, host revision, visible port label, present connector type and measured cable route. Ask the seller to identify the exact connector version and any required accessory or approved extension in writing. Keep that information with the live lux test so the next replacement can be matched to the same installation.