Choose the P10 outdoor LED module scan mode with the receiving-card configuration in hand. LED-Mall’s 1/2-scan and 1/4-scan SMD3535 boards share a 320 × 160 mm outline and a 32 × 16-pixel matrix. They use different drive modes and have different listed maximum power consumption. For a new display, select one supported module SKU, confirm the exact driver and usable settings on a sample, then buy the production quantity as one batch.
If you are trying to repair an older display, send its original module label and cabinet details to the original supplier. Both of the LED-Mall listings compared here say they are supplied for same-batch screen builds and are unsupported as spares for existing older displays. Use this guide to prepare a new screen or a fully reviewed rebuild, where you can validate the module, control system and cabinet together.
1. How the P10 outdoor LED module scan mode affects the order
01. Start with the model number and drawing
Das P10 1/2-scan module und P10 1/4-scan module both use a 10 mm pixel pitch and SMD3535 LEDs. Their listed module dimensions are 320 × 160 mm, about 12.60 × 6.30 in. Both specifications give 32 pixels across and 16 high. Those figures let you compare the screen grid using the same cabinet count. The product-specific driver, scan and power fields still belong on separate rows in your engineering and purchasing records.

Scan describes how the board drives groups of pixels in succession. The stock sheets identify both models as constant-current modules and specify a 1/2 or 1/4 duty ratio. Get the offered P10 outdoor LED module scan mode from the exact quote and module specification. The label gives you a starting point for control-system selection. The driver IC, board wiring, data grouping and required refresh and grayscale settings determine what the receiving card must actually do.
What stays the same and what changes in the module specifications
| Feld | P10 1/2 scan | P10 1/4 scan | Verwendung bei der Kaufentscheidung | |
|---|---|---|---|---|
| LED package and pitch | SMD3535, 10 mm | SMD3535, 10 mm | Keep the bill of materials tied to the exact LED-Mall model, even when the package is shared. | |
| Modulübersicht | 320 × 160 mm | 320 × 160 mm | Confirm fixing points, mask and installed depth for the cabinet drawing. | |
| Aktivmatrix | 32 × 16 Pixel | 32 × 16 Pixel | Use these values to build the receiving-card map and count the pixels. | |
| Listed drive mode | Konstantstrom, 1/2 Einschaltdauer | Konstantstrom, 1/4 Einschaltdauer | Request a validated configuration for the supplied scan and driver combination. | |
| Listed maximum board power | 40 W | 28 W | Use each number for the specified board. Have the cabinet engineer evaluate the complete electrical load. | |
| Ordering restriction | Whole-screen same-batch order | Whole-screen same-batch order | Include planned spares for the new screen at the time of ordering and confirm the scope with LED-Mall. |
The example products are both documented at the module level. Treat any project-level rating, such as cabinet sealing or completed-screen brightness, as a separate requirement to validate on the assembled system. If your buying decision depends on an optical figure, ask for the specification tied to the production version and the settings at which it applies. A P10 outdoor LED module scan mode alone cannot tell you how the finished screen will look in its installed environment.
2. Match the receiver before committing to a batch
01. Ask for the module revision and control-system requirements

Get the exact module revision along with the P10 outdoor LED module scan mode. Ask which receiver, hub connection and supported software were used to configure that version. A wiring drawing should show where each ribbon goes and which end of the chain takes data from the receiver. Request the driver IC identification and the settings file or documented setup procedure supplied for the sample. Record the cabinet width and height in pixels so the file and the proposed layout can be checked together.
The scan label and the file are related purchasing inputs. A file that worked on a different 320 × 160 mm board may contain a different row or data-group map. If the supplier offers a second module as an alternate, request a separate file and compatibility check for that board. Keep each file under its sample revision and include the matching quote line number in the filename or service record. This matters when the two candidate modules occupy the same space on a bench and all the sales photos show the front mask.
02. Look for the evidence a usable configuration leaves behind
Review one assembled reference cabinet under the intended control conditions. Start with a test image that gives each module a unique position label. A numbered grid makes it easy to spot a branch whose destination is shifted. Then use patterns with single colors and boundaries between rows, plus moving content and low-gray material where these matter to the application. Have the integrator record what settings were used and keep any observations with the module drawing. The P10 outdoor LED module scan mode on that record should match the board documentation and the supplied receiving-card file.
If an entire row repeats or appears in the wrong location, use the position pattern to identify which path is affected. A repeatable fault gives the supplier a narrower starting point than a video of a busy animation. Share the diagram, file revision and test pattern with whoever prepared the settings. Avoid treating a symptom as proof that you selected the wrong duty ratio, since mapping, cabling, software settings or a module fault can create similar results.
Run the same sample again after the integrator saves its settings and restarts it using the approved service procedure. Record both the startup image and the final test image. One test shows what the panel can display under the current settings. The restart check shows whether the cabinet returns to the expected state with the settings it will have in service. Before ordering, ask the integrator which parts of the configuration must stay with the replacement records, including the board-level file and the screen-level map if the control system stores them separately.

3. Put the geometry and power on separate sheets
01. Count the screen in modules and in pixels
Suppose the sample design has four modules across and four down, all mounted in the same orientation. Each board is 32 × 16 pixels. The 16-module design therefore maps to 128 × 64 pixels, or 8,192 pixels in total. Multiplying the module outlines gives a nominal tiled face of 1,280 × 640 mm, about 50.39 × 25.20 in, before allowing for the actual cabinet edges or panel construction. Those calculations are the same for either listed P10 outdoor LED module scan mode. Give the cabinet builder the mechanical drawing and give the control integrator the pixel map.
Document how many boards each receiving-card cable serves and how the cables cross the cabinet. A drawing that simply says 128 × 64 leaves the port assignments open. If the first prototype uses a different cable path from the finished cabinet, record the difference and repeat the map check on a production-representative assembly. Order the control hardware after the integrator confirms that the populated branches fit the supported layout at the intended scan, refresh and grayscale.
02. Compare module maxima under the same assumed layout
With the same 16-board example, multiplying the stated maximum per module gives 640 W for the 1/2-scan variant and 448 W for the 1/4-scan variant. These are sums of published module maxima for the two exact products, before any allowance for other cabinet loads, distribution or supply losses. They do not describe typical electricity use. They also do not show that selecting a certain P10 outdoor LED module scan mode causes a particular energy saving. The boards and their rated conditions may differ in more ways than scan duty.
Ask the cabinet engineer to use the verified ratings for the offered module, add the documented loads from the controller and other hardware, and assess the required operating and ambient conditions. The electrical design should treat panel current, usable supply capacity and protection as separate items for qualified review. For purchasing, keep the module SKU and the cabinet design revision next to the power budget. When the module changes, check whether the approved design still covers it before reusing the supply list.
In a taller design, the same module count could be arranged two across and eight down. The face would then map to 64 × 128 pixels, with a nominal tiled outline of 640 × 1,280 mm (25.20 × 50.39 in). The sums of board maxima would stay the same because the quantity is unchanged. The different geometry could change where the receiving card and distribution paths belong. Keep shape, pixel capacity and peak module count as distinct entries when someone asks whether a stock cabinet and control package will fit the project.

4. Put same-batch requirements in the order
01. Order the complete new-screen quantity together
Both product pages ask buyers to purchase all modules for a screen together because different production batches can vary in color and brightness. Include the expected production count and the spares intended for that new screen in the same quote request. In the 16-board example, an integrator who wants two future service spares can request 18 modules and ask the supplier to confirm that all 18 will come from the same batch. That number is a planning example. Select your actual spare quantity according to the service plan and supplier offering.
Ask how the sample relates to the production batch. A lab sample may verify the module family and its control settings. If the final production version differs, ask which differences require a new sample or another configuration check. Put the P10 outdoor LED module scan mode, model, approved settings-file reference, quantity and matching batch requirement together on the order line. When cartons arrive, match their markings to the approved sheet before allocating them to jobs or a service shelf.
02. Check the packaging and the spare record
Each current product listing says the module is supplied with an inter-module signal cable and a power cable. Ask for the length and style your cabinet uses before assuming those leads will fit a particular route. List supplemental harnesses and any other pieces separately so the quote states what is included. The outdoor module catalog contains other formats. If the offered substitute appears under a similar name, compare the exact model and product drawing before adding it to the same bill of materials.
Give the receiving team a photo of the sample label and the vendor’s exact order line. They can use the two together to spot cartons with a similar product-family name but a different scan entry. Have the technician label the accepted sample and retain its documented configuration before taking it out of the test cabinet. If a carton marking differs from the approved record, hold that carton for identification before it is mixed with the others. This is especially useful when the same receiving department is handling modules for several displays in one week.
| Artikel | Beweise, die aufbewahrt werden müssen | Frage zur Veröffentlichung |
|---|---|---|
| Board and scan | Photo of rear label, exact SKU, driver and documented P10 outdoor LED module scan mode. | Does the vendor’s quote describe the board checked on the bench? |
| Mapping | Receiver model, configuration release, cabinet map and tested software version. | |
| Can the intended pixel layout be reproduced from these records? | Image at the target settings | Position pattern, color and low-gray observations under the required mode. |
| Did the representative sample meet the project’s image criteria? | ||
| Cabinet fit and design | Approved drawing and service clearances plus the cabinet engineer’s load decision. | |
| Does the confirmed assembly match the parts and conditions being purchased? | Produktion und Ersatzteile | Total order quantity, same-batch confirmation and expected carton markings. |
| Can the receiving team identify the spares that belong to this wall? |

5. Know when to place a different request
If your work order says “replace one failed 320 × 160 P10 module,” ask the original cabinet maker to identify the supported spare. The two linked product pages expressly exclude spare-part support for older displays. Matching pitch and outline leaves questions about PCB revision, connector mapping, mask, calibration and batch. Keep a new-screen listing tied to the type of order it supports. A planned rebuild belongs with a new, documented cabinet and control-system approval.
For a new installation, the two product pages give enough information to start comparing the options. You can establish dimensions and pixel count immediately, budget from the exact board’s published maximum and request the information needed to approve one P10 outdoor LED module scan mode. If you have only the brief and the cabinet sketch, send them before preparing a parts list. A quote request can identify which choices need a sample or a config file before a production order is placed.
If the old screen is being rebuilt cabinet by cabinet, tell the supplier what remains in service and where the new modules will go. Existing cabinets may need to run alongside the new assembly during the transition. Ask the integrator to check the scope for that phase, including the control system, service access and acceptable image variation between the two sections. Treat an approved bill of materials for an all-new cabinet as approval for that configuration. The phased layout deserves its own review.
Häufig gestellte Fragen
Can I copy a 1/2-scan file to a 1/4-scan board?
Request the settings for the exact module revision and receiver. The P10 outdoor LED module scan mode is one part of that file. The driver type, wiring and map must also match the hardware.
Does a difference of 12 W per module tell me what the display will cost to run?
It is the difference between listed maxima for the two boards. An operating-energy estimate needs the actual display configuration, content, brightness schedule and complete system energy use.
Does 320 × 160 mm tell me the fixing-hole positions?
Use the outline to plot the module grid. Ask for the exact drawing for fixing points, depth, fasteners and service access. Confirm the drawing against the sample cabinet before ordering the whole batch.
Can I get the same batch again when I need more spares?
Confirm what the supplier can reserve during the initial order and identify the spares on that order. Availability of a matching production lot months later depends on the supplier’s stock. Store the labeled spares with the wall’s cabinet and configuration records.
Which P10 outdoor LED module scan mode should I choose for my receiving card?
Choose the board that has a verified pairing for the exact receiver, driver IC, pin mapping and required settings. Ask for the approved configuration and test it on the proposed cabinet before committing to the full quantity.
Can the front of the board show me which scan version I have?
Check the rear label, the exact supplier specification and the configuration tied to that module. The two models use nominally matching front dimensions and package, so a face photo alone leaves the scan and revision open.
Ask for a quote for one complete display
Send LED-Mall the intended width and height in modules, the desired pixel dimensions, the proposed receiver and cabinet drawing, and your total quantity with spares. If the P10 outdoor LED module scan mode is still open, include the project’s target settings and ask which revision and configuration should go on the quote. Ask LED-Mall to review the module order and specify that the production units and service spares are for the same new display.

