Size a NovaStar MX40 Pro port load at the wall’s output bit depth and frame rate, then repeat the math with whole cabinets. At 60 Hz, a 3840 × 2160 wall needs at least 13 outputs at 8-bit, 17 at 10-bit with the faster supported receiving-card family, or 26 at the lower 10/12-bit limit in NovaStar’s specifications. Those are lower bounds. A sample wall built from 144 identical cabinets needs at least 14, 18, or 29 runs once each receiving chain has to stop at a cabinet boundary.
The difference can change the quote. The MX40 Pro has 20 physical Gigabit Ethernet LED outputs. A plan that calls for 29 active runs needs a different distribution design from a 14-run plan, even though both show the same number of wall pixels. Get the display engineer and whoever is pricing the fiber, cabinets, and spare hardware to use the same operating mode and the same port schedule.
1. Choose the NovaStar MX40 Pro port load limit
Start with three numbers beside every candidate map: the number of active pixels in the wall, the per-port allowance at the operating mode, and the number of outputs available for active branches. The MX40 Pro controller listing identifies the processor. NovaStar’s MX40 Pro LED Display Controller Specifications V1.5.0 and V1.5.1 describe its current output modes, Ethernet capacity and receiving-card conditions. An older sheet can show different figures, so add the applicable document revision to the quote.

01. Separate the video input from the LED output
A source labeled 10-bit tells you about the incoming signal. The number to use for NovaStar MX40 Pro port load comes from the Ethernet output mode and the receiving cards deployed in the wall. Record the incoming format and the intended LED output separately. A media server or switcher output of 3840 × 2160 at 60 Hz does not establish either field for the controller. Likewise, a controller’s mode change at rehearsal can alter the port budget even when the source resolution stays the same.
The V1.5.1 output summary puts the 60 Hz limits at 659,722 pixels for 8-bit and 494,791 for 10-bit with the A10s Pro or A8s Pro. The detailed capacity section extends the faster case to their derivative receiving cards. For other supported Armor series receiving cards, the 10-bit figure is 329,861. That is also the listed 12-bit figure at 60 Hz in both detailed tables. Use the lower published 494,791 figure when checking the faster 10-bit case, because the detailed table rounds it to 494,792. The examples here have enough room that the difference of a pixel changes no result.
| LED output and receiving cards | Pixels per output | Raw minimum for 8,294,400 pixels | Kaufimplikation |
|---|---|---|---|
| 8-bit with supported receiving cards | 659,722 | 13 | Check cable grouping before allocating the rest of the physical ports to other uses. |
| 10-bit with A10s Pro or A8s Pro family as specified | 494,791 | 17 | Confirm the exact supported receiving card on the cabinet bill of materials and firmware list. |
| 10-bit with other supported Armor cards, or 12-bit | 329,861 | 26 | Plan beyond 20 rear RJ45 outputs before reserving any standby runs. |
Each row divides 8,294,400 by the relevant per-port allowance and rounds up. It assumes all loaded pixels fit the published ceiling, so the count cannot go lower under those conditions. It can go higher. The unit also has a published maximum device load of 9 million pixels and maximum output width or height of 16,384 pixels. These are separate checks. Adding outputs or choosing a frame rate that allows higher per-port loads does not override the device-wide limits.
02. Check the receiving card and frame rate behind the number
Ask for the receiver label or a cabinet parts list with the offered part number, rather than a verbal assurance that the cabinets use Armor cards. In the faster 10-bit row, the family changes the NovaStar MX40 Pro port load allowance by roughly half relative to the lower 10-bit row. If the order calls for spares, record the approved replacement part as well. If different sections use different receivers, inventory the families by chain. For a chain with mixed hardware, get the allowable operating mode and loading confirmed for that exact combination before assuming the higher figure.
Frame rate has its own effect. NovaStar’s detailed table lists 247,396 pixels at 120 Hz and 10-bit for the A10s Pro or A8s Pro family and their approved derivatives, about half its 60 Hz entry. That figure is a capacity planning reference. Validate separately that the source format, cabinet driver settings, receiving hardware, and planned operating mode can actually run at 120 Hz. Quote the tested target rate, even if the client sends a lower-rate sample file for the prebuild.

2. Pack whole cabinets onto each run
Imagine a full rectangular UHD wall with 12 columns and 12 rows of 320 × 180-pixel cabinets. This is a planning example, with 144 cabinets and 57,600 pixels each. A copper output feeds a chain of whole cabinets in this design. To see how many cabinets fit on an output, divide the allowed pixels per port by 57,600 and round down. Then divide the cabinet count by the result and round up to get the minimum number of runs. This cabinet-by-cabinet check catches the shortfall hidden by a raw NovaStar MX40 Pro port load calculation.
| Mode at 60 Hz | Maximum cabinets per run | Loaded pixels on a full run | Minimum runs after packing | One possible count before routing checks |
|---|---|---|---|---|
| 8-bit | 11 | 633,600 | 14 | 13 runs of 11 and one run of 1. |
| 10-bit, faster receiver row | 8 | 460,800 | 18 | 18 runs of 8. |
| Lower 10/12-bit row | 5 | 288,000 | 29 | 28 runs of 5 and one run of 4. |
Those example groupings are arithmetic. Give the cable crew a route they can install and the service crew a route they can trace. A vertical-only map with adjacent cabinets might use one run per 12-cabinet column at a different allowance, but here the maximum is 11, eight, or five. If the installer chooses to keep every run entirely within one column, the 10-bit eight-cabinet case needs two runs per column and 24 altogether. That would exceed the controller’s 20 physical Ethernet connectors even though 18 runs is mathematically possible. A different grouping can cross columns by following adjacent cabinets, provided the resulting physical route and controller map can be accepted for the venue.
For this rectangular example, draw groups two cabinets wide and four cabinets high. Six groups fit across the wall and three fit down, giving 18 groups of eight cabinets. Each group represents a 640 × 720-pixel patch and contains 460,800 pixels. A chain can snake down one column in the patch and back up the adjoining column. Use this as a drawing exercise. The cabinet connector locations, service access, jumper length, and approved data direction still determine whether it can be wired as drawn.
The same 18 groups leave 33,991 pixels of arithmetic margin apiece in the faster 10-bit mode. A ninth cabinet would need 57,600 pixels, so the spare capacity cannot fit another full cabinet on any of those groups. If the production adds a cabinet column of the same size, draw its own groups and include the added pixels against the device-wide cap. Adding one column of 12 cabinets brings the display to 8,985,600 active pixels. That is close to the published limit before assessing the revised map or the next possible expansion.
01. Name the first and last cabinet on every route
A drawing that colors each group by port should show its first cabinet, last cabinet, jump direction, and connector arrival point. Starting a short chain on the wrong side can add a long return cable, cross a service seam, or put branches that the crew intended to keep together in different patch bays. Show cable routes and the cabinet drawing side by side. Where service access limits the route, carry that constraint into the count before pricing equipment.
For a wall with mixed cabinet sizes, use the sum of the actual cabinet pixels on each run. Spare space on one output does not absorb an overloaded cabinet on another. Use the display grid rather than a rectangular input canvas where the physical LED wall has cutouts or offset sections. Under V1.5.1, each rectangular load area narrower than 128 pixels can reduce a port’s capacity by the missing width times that area’s height. For example, a 96 × 480-pixel strip uses 46,080 active pixels and incurs a 15,360-pixel capacity deduction in that calculation. If the drawing uses narrow strips, include the deduction in each affected NovaStar MX40 Pro port load row.

3. Turn the port count into a cable schedule
Count physical copper jacks, optical groups, and standby assignments separately. A 20-port chassis can carry 18 physical active branches if the map fits its rear outputs. That leaves two physical jacks before considering the project’s reserve strategy. The same unit can also use optical distribution with suitable NovaStar hardware. Its 40-port optical mode assigns four banks of ten logical Ethernet branches to OPT 1 through OPT 4. The fiber equipment at the other end has to produce the intended copper drops, and every branch still has to fit the applicable NovaStar MX40 Pro port load limit.
In 20-port optical mode, OPT 1 and OPT 2 carry the first two port banks, and OPT 3 and OPT 4 are copies of those banks respectively. Copying a bank repeats the same branch assignments. In 40-port mode, OPT 3 and OPT 4 can carry branches 21–30 and 31–40. If you enable Ethernet port backup in that mode, NovaStar documents that the second twenty back up the first twenty. Confirm the mode and the availability of active branches with the designer who owns failover. A 29-active-run quote and a 20-primary-plus-20-backup quote are different equipment schedules.

Put the optical module type, far-end hardware, bank allocation, and local copper branch numbers in the quote notes. NovaStar’s specifications say the controller does not include an optical module by default. Confirm the optics and compatible converters as line items where fiber is needed. When the optical and physical paths share the same output assignment, the published priority rules apply. Mark which path is actually intended to carry that assignment. A neat port chart that uses a copper and optical copy as two independent loads can be wrong even with all individual chains below the ceiling.
Where the project calls for backup, document the failure the design must cover. A break in the final copper run and loss of a whole optical path are different events. Assign a test and an expected screen response to each included scenario. If the system needs to hold 10-bit operation during fallback, check NovaStar MX40 Pro port load on the alternate route at 10-bit too. This is a purchasing constraint whenever the proposed fallback has a different controller, card family, or number of usable runs.
4. Verify the map at the intended show settings
Before shop acceptance, review the proposed map in VMP and keep a printed or exported copy with the build. Enter the intended cabinet dimensions and receiving hardware. Compare the mapped loads with your written NovaStar MX40 Pro port load schedule. Once the hardware is connected, put up a cabinet-number or grid image. A reversed row can still light up all its pixels, so check location and order as well as a full-screen image. Run a moving edge and a grayscale ramp at the output settings specified for the job.

Rehearse a preset change if the production will switch between presets or source formats. Capture the source timing, the configured output timing, and the last cabinet lit on each heavily loaded run. If a high-depth rehearsal produces a missing end section or intermittent artifacts, check the chain order, receiving hardware, cables, and mode-specific allowance before moving cabinets at random. A run that fits at 8-bit can be overloaded at 10-bit with the same lineup. Conversely, a short run that fails in both modes warrants a cabling and cabinet check as well.
Save the accepted configuration and the revised patch sheet together. Record where the actual system differs from the bid, such as routing two chains instead of one or changing a receiving card. If an owner later wants to raise the refresh setting in the source or enable a production feature, check which setting actually changes the LED output rate. Re-run the NovaStar MX40 Pro port load worksheet whenever the approved output mode or cabinet layout changes. Keep the old map available so the crew can return to the accepted baseline.
At handoff, agree on which evidence the client will keep. A cabinet-number still verifies where each chain lands. A port schedule marked with the active mode records what the designer intended. A short recording of the moving test and a dated configuration export help reproduce the condition if field symptoms appear later. Tie all three to the same unit and cabinet build so an earlier bench map cannot be mistaken for the installed one.
Give the venue an annotated patch sheet too. A technician can follow the controller output, the panel jack label, and the first cabinet without opening the design software. Where a fiber converter sits between them, include its rack and port label on the same line.
Questions that come up at quoting
Can I size the wall from its physical measurements?
Use physical dimensions to plan the install and the source aspect ratio. To check NovaStar MX40 Pro port load, use the native active pixel width and height per cabinet and the hardware actually assigned to each output.
Which receiving card should appear on the purchase order?
List the exact part the cabinet supplier approved, plus the revision or firmware requirements they specify. The A8s Pro-Empfangskarte is one of the named families for the higher 10-bit capacity. Its per-card loading and the controller’s per-output loading are two independent limits.
Can an irregular wall fit even if its input canvas exceeds its active pixel count?
NovaStar describes Ethernet port loading as the sum of the actual mapped cabinets. Calculate that load from the cabinets, then separately verify the source format, the controller output dimensions, and any capacity deduction for narrow mapped rectangles.
Why did another quote use 480,000 pixels for a 10-bit output?
Older MX40 Pro documents list a 480,000-pixel figure at 60 Hz and limit it to A10s Pro. Later V1.5.x specifications use the figures in this guide. Check the installed hardware, firmware, and applicable NovaStar document before revising a design already in service.
Do I need to allow for every planned standby jack in the first quote?
Include any required standby path in the first cable and equipment schedule. Show how it is assigned and how it will be tested. The load carried in backup mode and the number of ports reserved for that purpose both affect the quote.
Can I approve a purchase with a screenshot of the wall layout?
A layout screenshot shows the geometry. Add the intended output modes, receiver models, per-port pixel totals, output bank assignment, and physical route. Include the current approved cabinet configuration record where relevant, and confirm the configuration format needed for the deployed VMP workflow.
Quote from the cabinet map
To check NovaStar MX40 Pro port load before ordering, send the cabinet dimensions in pixels, cabinet count, receiving-card model, intended output bit depth and frame rate, and your preferred copper or fiber topology. Include the length and endpoint of each optical route and mark any run intended for backup. Send LED-Mall the port schedule for a configuration quote so the controller, compatible accessories, and any receiving cards can be matched to the same design.